Re:The effects of grounding on inflammation
by jfengel on Monday August 29, 2022 @02:38PM
(#32641830)
Clamp a meter around the lead wire.
[ Parent
| on HN ]
Re:The effects of grounding on inflammation
by marginalia_nu on Monday August 29, 2022 @02:49PM
(#32641963)
Yeah, good point, that would do it. I was thinking of measuring current between the patient and the interface somehow. That would be a lot less trivial.
Re:The effects of grounding on inflammation
by perihelions on Monday August 29, 2022 @03:00PM
(#32642086)
You could plug two hot wires into the patient and measure their current imbalance: the difference is ground-loop leakage. That's how GFCI breakers work!
Re:The effects of grounding on inflammation
by marginalia_nu on Monday August 29, 2022 @03:25PM
(#32642400)
Seems close enough to an ECG that you might end up with a fairly noisy signal.
You would be attempting to measure very weak, probably DC, currents. Something that could clamp on wouldn’t be sensitive enough.
Re:The effects of grounding on inflammation
by kazinator on Monday August 29, 2022 @03:59PM
(#32642806)
Discharge through a tiny (fraction of an ohm) current-sensing resistor, measuring the voltage across it.
Re:The effects of grounding on inflammation
by vorpalhex on Monday August 29, 2022 @03:23PM
(#32642375)
You can easily amplify the signals in question. This is a good first circuit problem for a kid.
No you can’t easily amplify the signal from a current clamp. That’s why they’re never used for sensitive measurements.
You wouldn’t clamp something on, you would use a sense resistor.
Re:The effects of grounding on inflammation
by vorpalhex on Monday August 29, 2022 @03:42PM
(#32642601)
You can literally buy a Fluke meter good down to 4ma with 0.2% accuracy: https://a.co/d/d8MZFKC
Re:The effects of grounding on inflammation
by heisenzombie on Monday August 29, 2022 @04:19PM
(#32643019)
The currents would be much less than 4mA.
I’ll try to estimate the most current we could expect. Some googling throws up that a human body has ~30pF of capacitance, and that static electricity can be up to 20kV in very dry conditions. That’s 600 nanocoulombs of charge. If we guess that you’re building that up once once every minute (what a terrible existence, getting a big shock 60 times an hour!), then the grounding strap would be carrying ~10nA continuously.
10mA is enough to lose control of your muscles. 4mA is incredibly insensitive [1] compared to a more direct measurement, with volts from electrons, rather than trying to measure their weak magnetic field, at a distance, as they zip by. With a sense resistor, you can use a bench top voltmeter [2] to measure nA.
1. 10fA resolution, over 400 billion times more sensitive: https://smt.at/en/products/electrometer-nv-meter/picoamperem...
2. > 1 million times more sensitive, with GΩ sense resistor: https://www.keysight.com/us/en/assets/7018-06774/data-sheets...