Re:Toyota unveils 8.7 kWh battery for residential applications by taneq on Monday June 13, 2022 @09:12PM (#31733674)
Technical nitpick, if it detects earth leakage and trips based on that, it's an RCD, not just a circuit breaker. Otherwise yeah, there's different approaches to earthing - in Australia for domestic stuff we have mandatory RCDs which work as you describe above, but then also in industrial/mining settings we have the big green/yellow cables which will directly sink current (potentially hundreds of amps) to ground, hopefully stopping you from getting bitten.
Re:Toyota unveils 8.7 kWh battery for residential applications by rainbowzootsuit on Monday June 13, 2022 @11:05PM (#31734304)
A thermal breaker won't trip on leakage current or arc faults either. I was trying to describe the classic "dead short" that will trip a thermal circuit breaker or fuse without the circuitry for arc or leakage detection.