Which is exactly why we need to get away from those 12V old garbages asap. 12V is so bloody wasteful, in terms of both wasted power and wasted conductor material. The only reason why its still around is people got used to it and don't wanna change.
Assuming this means highest voltage that's still mostly safe and does not require a whole bunch of insulation, we might be looking at something from 80 to 100 VDC? No idea where I read it from but apparently it takes about that much DC voltage for people to "feel something" when touching conductors with dry skin.
Below those levels, you have only general product safety regs to comply with. At/above those and up through all “reasonably household” voltages, you (probably) have to comply with the EU low voltage directive. “Probably” because the LVD itself isn’t law but member states have generally implemented it in their laws.
Correcting the power factor from 120VAC gives you a boost circuit that gives you 360-400VDC. Some motor control and battery technology standardizes around this voltage. Cars are a big one, but also PFC direct to inverter motor control, which is becoming popular in white goods.
What does breaking skin mean in this context? My understanding was that humans largely act like a resistor with some parasitic capacitance and inductance. Wouldn't more voltage equal more current in a mostly linear relation?
see for instance: https://www.vicorpower.com/documents/whitepapers/wp-boosting...
Having DC power at home seems like the worst of both worlds. Low voltage DC at home causes large losses in the wiring, and high voltage DC causes large losses in the step-down regulator (leaving you with a buck-type regulator operating at the low extreme of its duty cycle). After all, DC-DC conversion relies broadly on turning the DC into something vaguely sinusoidal and using an inductor - so its basically DC-AC-DC anyways.
Am I missing something?
When you decrease the voltage to 12 you start having to think about fatter wire--especially in larger homes--and that retrofit would be expensive.
That is not a new idea obviously, that exact approach has been in use in the telecom industry for decades. There is a AC feed to a system of rectifiers that converts the AC from the grid to -48VDC and continuously charge a string of batteries. There is a Generator that will go on automatically if the power from the grid fails and takes over.
The -48VDC is distributed throughout the central office to the equipment bays. There are a number of benefits to doing it this way, the batteries help maintain a constant voltage level and provide back up until the generator can fire up or if the generator should fail to start it buys you time to get it going.
For a home, I could see having a DC distribution system using USB 48V standard or maybe a 12VDC system with a wall battery and perhaps Solar system. Assuming that you could power all your devices off DC, it would eliminate the need for an Inverter. Most devices in homes today can be powered with 12VDC versions, with some exceptions.
It's an interesting idea.