News for hackers. Stuff that matters.
Re:Heartbreaking: 6509 PSUs Fail After a Brief 22 Years of S... by newaccount74 on Saturday January 29, 2022 @05:00AM (#30125166)
How long do those NTCs take to reset? Maybe that explains why the breaker trips after I turn it back on after a power failure -- if those NTCs are still warm, they would not limit the inrush current.
Re:Heartbreaking: 6509 PSUs Fail After a Brief 22 Years of S... by formerly_proven on Saturday January 29, 2022 @05:22AM (#30125256)
Modern high efficiency PSUs should have no problem with this, because their active PFC limits input current. NTCs also reduce efficiency and don't work when toggling power, unless you add a relay to short it out. They're a hack.
Re:Heartbreaking: 6509 PSUs Fail After a Brief 22 Years of S... by asddubs on Saturday January 29, 2022 @05:58AM (#30125422)
if you're gonna short it out, you can just use a resistor though
Re:Heartbreaking: 6509 PSUs Fail After a Brief 22 Years of S... by formerly_proven on Saturday January 29, 2022 @06:39AM (#30125568)
You need to use an NTC that'll stay within power limit under load to avoid a fire hazard when the relay doesn't work; if you try to do the same with a normal resistor you need large and expensive power resistors.