Re:Automating My Air Conditioner by sxp on Saturday October 09, 2021 @05:50PM (#28813617)
> If the temperature is above 75°F, the job turns the smart plug on. If the temperature is under 73°F, the job turns the smart plug off.

Would turning on/off a high current A/C like this have any negative consequences? Some A/C units have a cooldown period after you turn them "off" via their button since they need to remove some condensation and perform other normal maintenance. Would that issue apply to cheep window A/Cs?

Re:Automating My Air Conditioner by brian-armstrong on Saturday October 09, 2021 @05:51PM (#28813624)
Yeah you will get condensation with these window units too. It might have a pan that has to be drained.
Re:Automating My Air Conditioner by dguo on Saturday October 09, 2021 @06:32PM (#28813940)
I believe most window units instruct you to set them at a slight angle so that condensation can drain out the back without manual intervention. At least mine do.
Re:Automating My Air Conditioner by londons_explore on Sunday October 10, 2021 @01:59PM (#28820534)
The relay you use to turn it on better be rated for the startup current of the AC unit (which will normally be pretty high).

When turning it off, you should wait at least 1 minute before turning it back on. Repeatedly not waiting a minute will burn out the AC compressors safety circuit.