Re:Update about the October 4th outage
by robinson-wall on Tuesday October 05, 2021 @05:41AM
(#28757165)
It's still possible to design a badge system on an independent network (think just switched within a building) which syncs a local copy of the authoritative ldap from the corp domain, so your badge readers stay working if the link to the corp domain goes away.
It's just more expensive and another thing to maintain, and still doesn't account for _all_ failure modes (what if you sync really frequently and a bad change was made deleting all accounts?)
Re:Update about the October 4th outage
by raverbashing on Tuesday October 05, 2021 @04:35AM
(#28756792)
Sure, this fits under the "few actual reasons" but think for a moment: does it make sense that access to a building is controlled only (keyword here) through a centralized location somewhere? Some DB who knows where? With no fallback?
You might need a break-glass account/badge somewhere. Sure, the angle-grinder works, but probably cost you 2h maybe?
> it's likely not on an fb subdomain, but something like office.security.fb-infra.com
Thanks, yeah, makes sense
Akso, it's likely not on an fb subdomain, but something like office.security.fb-infra.com (example). It just happens to be that fb-infra.com is using the Facebook DNS server.