It represents less than 10% of the max power output of the plant (380 MW)
When I read "The battery section will provide four hours of storage capacity at full discharge" I understand that it will provide 4h x 30MW = 120 MWh of energy. Do you understand it as 4h x 380 MW = 1520 MWh of energy ?
[EDIT] From other source [1] it seems my interpretation is the correct one: "The onsite battery storage facility will be capable of providing 30MW of continuous power for four hours."
That completely changes the narrative: the total energy the battery storage can deliver by itself is less than what the solar + wind provides at full power in half an hour. Also, this amount of energy will be delivered at a peak power of less than 10% than the peak power of Solar + Wind
[1]: https://www.nsenergybusiness.com/projects/wheatridge-renewab...
Anyway, I think it’s reasonable to think in terms of “50 MW of PV solar and 30 MW * 4h of battery storage” + a wind farm because they normally charge batteries from solar via DC to avoid DC>AC>DC losses. But it might be a true hybrid system.
So you'd have to transform the electricity to high voltage, low current. But we already do that to pretty much arbitrarily lower Ωlosses on high V lines - the USSR made a transcontinental line back in the sixties with MV (yup, mega volts).
Optimistically, it’s just about possible in principle if you don’t mind paying SpaceX to expand by a few orders of magnitude. But I don’t think anyone will be very happy with even one gigawatt of orbital lasers, no matter how much the satellite owner insists (possibly even accurately and with reference to the laws of physics) that it can’t be turned into a death ray.
(And if you can use beamed power safely from orbit, with emphasis on safely, why not use the same beamed power horizontally at ground level around the world? Power at night from space implies an orbital-to-ground distance comparable to planetary radius).
There was a scifi short story, were a system was wrecked, aeons after a war, by what was essentially missed shots.
This is what makes the expanse so creepy. Every PDC round not finding a target- finds a target eventually. On the other side of the system, totally not intended, but it finds one. Even thinks doing the marathon with ion-engines can become lethally over time.
Voyager is another systems bullet.
Also, PV unlike concentrated solar does produce power during storms it’s just significantly less than normal.
Giant 3h system “400 MW of solar energy and store up to 1200 MWh of energy“: https://www.tdworld.com/distributed-energy-resources/energy-...
Example of using that for peak demand: https://www.reutersevents.com/renewables/pv-insider/giant-or...
To be clear a 4GW PV instillation would be 4GW * 4h or 16GWh. That 4GW produces ~30% of maximum output per day or 4GW * 0.3 * 24h = 28.8GWh per day. 28.8GWh - 16GWh = 12GWh after charging batteries. So for ~10h you get 1.2 GW with surplus charging batteries, and for the other ~14 you get 1.14GW.