Re:Why Don’t Green Buildings Live Up to Hype on Energy Effic... by blacksmith_tb on Sunday August 08, 2021 @06:28PM (#28110737)
I live in a Passive House[1] in the equally-humid Pacifc NW, without any kind of dehumidifier. I do have a Heat Recovery Ventilator (HRV) running 24/7, which pulls in fresh air from outside and exhausts indoor air, running them through a heat exchange as they pass each other to save some of the energy that went into the air while it was inside. As a plus it also runs the air through a MERV 13 air filter, which gets rid of pollen and some PM2.5 pollution.

1: https://en.wikipedia.org/wiki/Passive_house

Re:Why Don’t Green Buildings Live Up to Hype on Energy Effic... by throw0101a on Sunday August 08, 2021 @08:55PM (#28111650)
On the effectiveness of various MERVs on various PM sizes:

* https://www.greenbuildingadvisor.com/article/understanding-f...

* http://dx.doi.org/10.3390/ijerph120708448

* https://www.researchgate.net/figure/Mean-PM-25-removal-effic...

Just make sure your system can handle whatever MERV you go with (higher = more back pressure that needs to be designed for).

Re:Why Don’t Green Buildings Live Up to Hype on Energy Effic... by blacksmith_tb on Monday August 09, 2021 @10:56AM (#28117724)
Yes, I would go higher than MERV13 if I could, my HRV is a Zehnder, which doesn't support better filters without some modifications.
Re:Why Don’t Green Buildings Live Up to Hype on Energy Effic... by throw0101a on Monday August 09, 2021 @02:48PM (#28120674)
Ah yes, it seems that the built-in stuff has restrictions, but there are external boxes that can be added:

* https://www.zehnderamerica.com/our_products/comfowell-silenc...

Which allow MERV 16 and even carbon filters:

* https://www.zehnderamerica.com/product-category/comfowell/