Re:Passive radiative cooling below ambient airtemperature un...
by parineum on Friday July 09, 2021 @02:30PM
(#27786863)
This was my thought as well. I have an attic fan and monitor the temperature inside to control it. It regularly gets 120+ F in there on an 80 F day. I have to think the majority of the heating of my house is coming from the attic.
In the paper, the figure of 40 W/m2 seems to be the net cooling power, which is defined in equation 1 as being the power radiated away minus various inflows of heat: radiatively, from the atmosphere; radiatively, from the sun; and by conduction and convection. As far as I can see, these corrections are all for this particular surface, not the surface it might be replacing. These will not, in general, be the same, and, given that this new surface is both highly reflective and vacuum-insulated, I would guess that its values for these properties are lower than the conventional building materials on which the a/c rule-of-thumb is based.
Nevertheless, I doubt that replacing the entire roof with this material would be sufficient cooling, on its own, in the Australian case, and I agree that this would not likely be a straightforward retrofit, to say the least!