News for hackers. Stuff that matters.
Re:Nobody ever ported Doom to run on a Cray 1 by anonymousiam on Monday December 21, 2020 @02:15PM (#25498297)
Ohm's Law says 5.2V @ 770A is only 4.004kW. With one of these on each of the three phases, that's a total of 12,012kW.

So where did the rest of the power go, into cooling? Perhaps it was a linear power supply instead of a switcher? That would make for lots of inefficiency.

Re:Nobody ever ported Doom to run on a Cray 1 by kens on Monday December 21, 2020 @02:26PM (#25498403)
The Cray-1 has 36 power supplies: 20 that supply -5.2 volts, and 16 that supply -2.0 volts. (The weird negative voltages are for ECL, the fast logic family used in the Cray.) The bench around the Cray holds the power supplies.

Interestingly, the power supplies themselves are unregulated; regulation is done by the motor-generator unit.