I'd add that the other reason for using I/Q in heterodyned demodulation is for SSB (Single Side Band) to reduce out of band interferers. Otherwise both Fmix +/- Ffilt will get through. Usually, transmitters are also SSB to reduce power (unless they are baseband direct modulation).