Re:A 189 Year Old Limitation on Inductor Size Has Been Broke...
by AHappyCamper on Friday August 28, 2020 @12:11PM
(#24306610)
But it's a good start, no? And the theory has been proven as sound. I'm guessing/hoping they'll target the higher ranges soon.
[ Parent
| on HN ]
Re:A 189 Year Old Limitation on Inductor Size Has Been Broke...
by wbraun on Friday August 28, 2020 @02:16PM
(#24308219)
Its a material that basically gives electrons "inertia" which acts like an inductance derived from magnetic fields. There is a time constant to it, which determines at what frequency range it starts contributing to the inductance value.
To make it useful for power electronics they would have to push out this time constant by at least 4 orders of magnitude, I don't believe the theoretical material properties support that.
You might see this shaving off a few mm^2 from RF ICs and providing better RF performance. Applications in power electronics, where inductors take up the most volume, seems unlikely.
Re:A 189 Year Old Limitation on Inductor Size Has Been Broke...
by superkuh on Saturday August 29, 2020 @05:48PM
(#24319651)
On the flipside, kinetic inductance detectors (https://en.wikipedia.org/wiki/Kinetic_inductance_detector) for astronomy have been around since ~2000 and in the low light single photon regime they have much less noise on readout than photoelectric detectors (CCD/CMOS/etc).
Re:A 189 Year Old Limitation on Inductor Size Has Been Broke...
by rini17 on Saturday August 29, 2020 @05:21PM
(#24319531)
Perhaps power electronics will move to higher frequencies, too.
Re:A 189 Year Old Limitation on Inductor Size Has Been Broke...
by coryrc on Saturday August 29, 2020 @09:25PM
(#24320601)
Will have to drive gate and source capacitance down a few orders a magnitude to make that a reasonable trade-off.