Re:More than 100 coal-fired plants have been converted to na...
by pfdietz on Monday August 10, 2020 @08:18AM
(#24108450)
More specifically, Brayton cycle with a Rankine bottoming cycle (combined cycle). Open cycle gas turbines are about as efficient as supercritical steam plants (but are much cheaper to build).
Re:More than 100 coal-fired plants have been converted to na...
by baybal2 on Monday August 10, 2020 @10:16AM
(#24109487)
An _average_ steam turbine plant is nowhere near as efficient as a big enough single cycle gas turbine.
A top tier boiler plan of course may well be approaching a smaller/cheaper turbine.
Converted plans will always loose out to gas turbine plants.