Re:Air conditioning's original purpose was to enable factory... by gruez on Wednesday June 24, 2020 @05:19PM (#23633994)
>but there's no reason why any _new_ house should NOT have a heat-pump

Are heatpumps always more economical than gas/oil? I know that natural gas almost always beats electrical resistive heaters in terms of cost, even though resistive heaters are more efficient than natural gas. Heatpumps are supposed to be more efficient than resistive heaters, but in areas with expensive electricity it still might be more expensive.

Re:Air conditioning's original purpose was to enable factory... by csours on Wednesday June 24, 2020 @05:40PM (#23634190)
>"even though resistive heaters are more efficient than natural gas."

You have to be careful about what you measure. Resistive heaters are 100% efficient by definition, but you have to look at the whole chain. The energy has to be converted from X (coal, natural gas, isotopes decay) to electricity and transmitted to your home. Only the last step is 100% efficient. You lose a lot of energy in generation and transmission of electricity.

Re:Air conditioning's original purpose was to enable factory... by lsllc on Wednesday June 24, 2020 @06:04PM (#23634388)
A heat pump is only moving heat from one place to another, it's not heating "resistively". So your energy cost is to run the heat pump, not to "heat" the house.

Having said that a typically, your system is designed for a 99% "heating" or "cooling" dry-bulb outside temp from the ASHRAE climatic design conditions based on your location.

For example. Boston (Logan Airport) the 99% heating temp is 12.3F, so you'd size and design your system for this to get your heated space to 70F. There's a secondary heat source that fires if the temps drop below this (which happens, the 99.6% heating temp for Boston is 7.4F and it often goes below 0F). This is often resistive, but could be a hydronic coil if you had an on-demand gas combi-boiler for hot water. This is also used in an air-source heat pump for de-icing the condenser. A ground source heat pump (aka geothermal) doesn't have this problem, but requires a well to be drilled (100ft per ton of heating/cooling) to provide ground water as a heat source.

Re:Air conditioning's original purpose was to enable factory... by hippich on Thursday June 25, 2020 @07:30AM (#23639390)
Austin, TX area:

We used to live in 1800sqft house built in 1992 in the affordable neighborhood (so fiberglass bats in 4x2 walls). Gas heater, electric cooling. Gas water heater. Gas stove (we don't cook much, so this one probably doesn't have significant effect). We regularly got a bill over $250 in the summer for electricity + gas. Sometimes over $300. In the winter combined bill would be around $150. In summer second floor was never comfortable (part of it was poor circulation I am sure, but part of it was HVAC not cooling well enough)

We also just finished new 3100sqft house. The new place doesn't have natural gas, so we decided to go all-electric - water heater, HVAC, cooktop/ovens, and new addition - pool-heater. Our electric bill now fluctuates between $200 - $280 year around. All appliances, including water heater, are heat pumps. Extra bonus - garage, where the water heater is located, is cool during summer. Both water heater and HVAC has resistive heating elements for very cold days (we get enough of these to matter).

I am sure I can get average bill lower a bit if I tweak pool water and heat pumps schedule.

The house has open cell foam installed around the envelope (so the attic is alright to be in even during the hottest days) and we have forced ventilation (since the house is sealed essentially).

The water heater (80 gal) I bought myself and it was $900 on ebay. Similar product bought at Home Depot would cost probably $1,200 - $1,400. A bit more than natural gas heater, but not prohibitively so. HVAC installation (2.0 and 2.5 tons units) was under $20k for the whole house. Not sure how much traditional gas+electric non-heat-pump install would be, but I don't think it would be significantly cheaper.

So yeah, at least for southern places, heat-pumps appears to make a big difference.

Re:Air conditioning's original purpose was to enable factory... by cmurphycode on Wednesday June 24, 2020 @05:42PM (#23634206)
I was curious about this a while ago and did some napkin math.

Natural gas is roughly $15 for 1 million BTU. There are 3412 BTU in a kwhr, so if you heated resistively, you'd need 293 kwhr to get 1 million BTU.

In my area, which I feel has pretty high electricity cost, we pay $.24 per kwhr, so that'd be $70.

Therefore, you need a 70/15 (4.666) COP for your heat pump to match natural gas by price. My understanding is that that would be an unusually high number for cold weather conditions.

Re:Air conditioning's original purpose was to enable factory... by lsllc on Wednesday June 24, 2020 @06:12PM (#23634449)
The State of NH Office of Strategic Initiatives has a nice Fuel Price comparison page that they keep up to date (and are adjusted according to cost per MMBTU):

https://www.nh.gov/osi/energy/energy-nh/fuel-prices/index.ht...

You can see that as of June 2, measured at $ per MMBTU (million BTU):

  Natural Gas           $8.31
  Oil                  $17.62
  Propane              $32.93
  Wood pellets         $21.92
  Resistive electric   $48.84
  Air src heat pump    $18.74
The fossil fuels are all measured assuming 80% heating efficiency, whereas for propane or natural gas you might well have a high efficiency unit up to 97% which gains you a bit more savings.

These prices may vary depending on location and also I think natural gas isn't that common in NH as it's a mostly rural state.

Re:Air conditioning's original purpose was to enable factory... by cmurphycode on Wednesday June 24, 2020 @06:15PM (#23634484)
Holy moly. That price per million btu is a lot less than the number I stumbled across. Makes it even more obvious.
Re:Air conditioning's original purpose was to enable factory... by lsllc on Wednesday June 24, 2020 @06:50PM (#23634751)
I'm really glad I recently replaced my old 80% efficient oil boiler with a 97% efficient natural gas boiler. My winter bills are less than half what they were and it barely uses any gas during the summer for hot water.
Re:Air conditioning's original purpose was to enable factory... by wcoenen on Wednesday June 24, 2020 @07:26PM (#23635028)
With 80% efficiency, you have to burn 1/0.8=1.25 units of fuel to get one fuel unit worth of useful heat. With 97% efficiency it's 1/.97≈1.03 units.

So if fuel prices and the amount of useful heat usage stayed the same, then your bill should be 1.03/1.25≈82% of what it was before. If your bill is "less than half" then something else must have changed.

Re:Air conditioning's original purpose was to enable factory... by 7786655 on Wednesday June 24, 2020 @07:52PM (#23635233)
He switched from burning oil to burning natural gas. According to the table, gas is way cheaper.
Re:Air conditioning's original purpose was to enable factory... by lsllc on Wednesday June 24, 2020 @10:15PM (#23636186)
Yes, I switched from an oil burner (#2 heating oil) to a high efficiency natural gas boiler. The other key ingredient is that the oil boiler was 20 years old and did not have "cold start" (so it always keeps itself at temp even in the summer).

Any modern boiler (gas or oil) will almost certainly be cold start, so it only fires when there's a call for heat. This alone probably saves a gallon of oil a day at least.

Re:Air conditioning's original purpose was to enable factory... by makomk on Thursday June 25, 2020 @05:34AM (#23638673)
There's a reason the Energy Saving Trust over here in the UK discourages people from replacing their gas boilers with heat pumps thinking it'll save them money, even though our climate is more suited to it than the colder parts of North America. Unfortunately, that doesn't stop our press pushing the idea we should go for heat pumps because Germany has. (They don't have such widespread natural gas connections to homes as the UK and so are reliant on oil-fired home heating, which as you can see has very different economics.)
Re:Air conditioning's original purpose was to enable factory... by mindslight on Wednesday June 24, 2020 @06:47PM (#23634719)
Remember, oil prices cratered over the past few months. I'd take the current numbers with a grain of salt.
Re:Air conditioning's original purpose was to enable factory... by AnthonyMouse on Wednesday June 24, 2020 @10:11PM (#23636163)
We also don't know what the long-term fallout is going to be. Natural gas has been unusually cheap recently because it's a byproduct of fracking for oil. But low demand for oil means less demand for fracking which mean less natural gas production.

It's really hard to predict where prices are going to be in a year, because you really have to predict how well the oil industry can predict future demand in this environment. If they shut down too much production and then demand comes back there could be a price spike. If they expect a quick recovery and are wrong, prices could remain on the floor for a good while.

Re:Air conditioning's original purpose was to enable factory... by lsllc on Wednesday June 24, 2020 @10:27PM (#23636265)
This is also the "off" season for heating oil, so it's usually cheaper.

According to the NH page, that price was June 2. For the Commonwealth of MA, as of late May it was $2.07 on average and it's down 33% on last year:

https://www.mass.gov/service-details/massachusetts-retail-he...

You can see it has dropped from $3.04 on Jan 7 2020.

Re:Air conditioning's original purpose was to enable factory... by DanBC on Wednesday June 24, 2020 @08:14PM (#23635362)
In the UK they want to move as many people as possible onto heatpumps, away from natural gas combi-boilers.

I don't know how it works for blocks of flats.

Re:Air conditioning's original purpose was to enable factory... by lsllc on Wednesday June 24, 2020 @10:46PM (#23636360)
If you don't want fossil fuels (even natural gas), then it'll likely be a ground source heat pump. You just drill a number of deep wells -- each 100' of well gives you about 1 ton of heating/cooling (1 ton is 12,000 BTU/hrs or ~3.5KWh). For a decent sized building you'd be looking at probably a dozen or two 1-2K ft deep wells.

The nice thing is, you don't need much room on site, you can even drill them into the basement after the foundation is done before the steel goes up.

With a split system, the heat-exchangers can be in the basement and the refrigerant (R410A) run to the air handlers located elsewhere.

Of course, the more you insulate the building, the less heating and cooling you need.