Re:Pre-built solar homes could make renewable energy almost ...
by maxdamantus on Sunday September 29, 2019 @08:10PM
(#21110566)
If you're using DC to transmit the same amount of power, you'll probably be using similar voltages (otherwise you're going to need thicker cables). I suspect DC is probably a greater fire risk in this case due to arcing. An arc is less likely to persist on AC since the potential keeps passing through 0 V (hence DC switches are designed to have a bigger air gap).
If it's just a matter of providing alternative circuitry for low-power devices, presumably you can already improve safety by just using lower-current circuit breakers.
Re:Pre-built solar homes could make renewable energy almost ...
by rodgerd on Sunday September 29, 2019 @10:27PM
(#21111262)
> If you're using DC to transmit the same amount of power, you'll probably be using similar voltages (otherwise you're going to need thicker cables).
A good point - I guess I'm mostly thinking about the volume of things in the house that don't really need access to even a fraction of the 2.4kW available; having moved from incandescent bulbs to LEDs, I've got a bunch of unnecessary power supply and per-bulb transformers, for example.
Given the degree of fire risk in houses that's associated with 230V/10A wiring and devices, I do wonder how much safer it would be to have fewer AC/DC transformers scattered around the house with DC wiring.