Re:Demon Core by bsder on Monday June 17, 2019 @05:00PM (#20207344)
> soldering on equipment plugged into mains

o_O!!!!!!!

I've cut a LOT of corners, but that one is just insane...

Re:Demon Core by hinkley on Monday June 17, 2019 @07:07PM (#20208194)
"But this is the ground wire so it's okay".

Hint: Lots of people have daisy chained outlets backward, and lots of AC circuits still work with the wiring reversed.

Pretty sure we found one where they had reversed them twice, so black was hot at the end of the circuit but not in the middle.

Re:Demon Core by xyzzy_plugh on Monday June 17, 2019 @07:52PM (#20208473)
I have no idea why I never considered this possibility. That's terrifying.
Re:Demon Core by firethief on Tuesday June 18, 2019 @02:46AM (#20210286)
I inspected all my outlets after finding out what 60VAC feels like going up one arm and down the other (touched two server cases, one on a grounded outlet, the other floating). I found several suprises: a knob and tube circuit had been "upgraded" to 3-prong faceplates without wiring the ground to _anything_, and some outlets were backwards. You never know if it's the work of a DIY electrician unless you get it checked out.
Re:Demon Core by protomyth on Monday June 17, 2019 @08:13PM (#20208611)
Someone hooked the washer and dryer into the mains at my Grandma’s house. It was interesting seeing my Dad go from confused to realization to angry without having caused the transition. Getting that fixed was an exercise in careful. As Dad is fond of saying “I’m amazed you thought of it and appalled you actually did it.”
Re:Demon Core by mirimir on Monday June 17, 2019 @10:54PM (#20209409)
I ran into that, in an old house.

Some decades ago, the house had two meters. One was just for the hot water heater. But when they removed that one, they just connected the water heater to the main meter. Directly. Not through the breaker panel.

Damn. Almost killed me.

Re:Demon Core by protomyth on Monday June 17, 2019 @11:13PM (#20209484)
Would have probably killed someone in our group except my Dad and one of my uncles had a bad feeling about it. Apparently working for Ma Bell will give one a sense of those things.
Re:Demon Core by jefftk on Monday June 17, 2019 @08:52PM (#20208855)
> Someone hooked the washer and dryer into the mains at my Grandma’s house.

Do you mean they wired it in parallel with the main breaker panel, so you couldn't disconnect it to work on it?

Re:Demon Core by protomyth on Monday June 17, 2019 @11:11PM (#20209473)
Yep. We flipped off all the breakers and the damn washer & dryer were still hot. My memory was a bit off and the the water heater and maybe stove were also hot. We had to replace all of that. I was 10 at the time so I was working on other stuff while Dad and the uncles took care of it. Putting in a new structural support beam was also enlightening.
Re:Demon Core by joefourier on Monday June 17, 2019 @08:36PM (#20208763)
Funnily enough that's a normal practice in the UK/Ireland. In all the places I've lived, washer and dryer are plugged straight into a regular outlet (sometimes with an extension cord if it can't be reached).

Makes me wonder, why not make a 110v washing machine and save the trouble of having both 110v and 220v at home?

Re:Demon Core by mikeash on Monday June 17, 2019 @09:24PM (#20209027)
Most (all?) washing machines are 120V. Electric dryers rarely are, because they need a lot more power. I had a small washer/dryer combo unit years ago that used 120V, and it took about four hours to dry a load that was about half the size of a normal dryer’s capacity.

Running both voltages into a house isn’t much of a burden. Residential electricity in the US is two-phase. A 120V circuit pulls from one phase, with the various circuits in your house divided between them to even out the load. A 240V circuit just connects to both phases.

Re:Demon Core by handelaar on Tuesday June 18, 2019 @03:46PM (#20217579)
Well yes, but we usually segment areas into their own circuits and in a well-built residence the laundry appliances get a fused circuit to themselves (or, at the very least, share one with the kitchen sockets). So your amperage/fuse-trip-point is isolated to that one group of sockets.

Plus as you semi-observe, everything on a socket here is 220V

Re:Demon Core by sk5t on Tuesday June 18, 2019 @12:46AM (#20209866)
I get the sense some of these posts are talking about devices connected directly to the building's supply wiring (not to a receptacle downstream of the circuit breaker panel).

In the US all residential washing machines are 110V, as are gas dryers, but electric dryers take 220V.

Re:Demon Core by Gibbon1 on Tuesday June 18, 2019 @01:08AM (#20209953)
The US uses split phase 240VAC for residential. 240VAC is really two 120VAC 'hots' 180 degrees out of phase. So 240V between phases, but 120V to ground/neutral.

Industrial 240 usually is single or 3phase.

Re:Demon Core by icedchai on Monday June 17, 2019 @09:25PM (#20209032)
110 (120 really) volt washing machines are very common, at least in the US. Dryers, on the other hand, are 240 here.