Re:TI Claims Breakthrough in BAW On-Die-Oscillators by tzs on Wednesday February 27, 2019 @12:54PM (#19265286)
Based on the video here [1] and some of the links on that page, plus assorted diagrams of other bulk acoustic wave resonators, I don't think there will be any problem.

Helium can interfere with devices that either depend having a vacuum in a volume or depend on having that volume contain a gas mixture with specific properties. Helium getting in messes that up.

The BAW on-die-oscillators do not appear to have any places that are supposed to be vacuum or supposed to contain gas. The have two piezoelectric thin films, with acoustic reflectors behind them. The gap between them appears to be solidly filled. All the relevant acoustic waves are carried in that solid stuff, not in air. (This also means, I think, that these things should be OK in vacuum).

[1] https://training.ti.com/tis-bulk-acoustic-wave-clocking-tech...

Re:TI Claims Breakthrough in BAW On-Die-Oscillators by SamReidHughes on Wednesday February 27, 2019 @06:39PM (#19267915)
The helium problem was because of helium working its way into the crystal structure of the resonator and affecting its springiness.