That said, I may not understand what a 'load dump' condition is, myself -- I always thought it referred to the common case where a high current load is switched off abruptly, causing the voltage to spike until the alternator's regulator circuit can respond by reducing the field coil current.
Disconnecting the battery would not be expected to cause such a condition, since the charging current is not all that high most of the time compared to other loads. I wouldn't expect much of anything to happen when disconnecting the battery from a running car. It should just keep running.
Alternators tend to produce a constant current in proportion to the field winding current (the variable the voltage regulator controls). When you disconnect the battery the alternator attempts to maintain that current by increasing the voltage. The voltage regulator has to reduce the current in the field to close to zero to stop this voltage surge. The field has some magnetic energy (inductance) that the voltage regulator has no good way to get rid of quickly. So the output voltage zooms up to maybe 10 times the normal voltage for an extended period and any electronics in the car might be very sad.
On a related note, I heard this 2nd hand from a guy who was talking to CAT about a module they wanted to have 80V over voltage protection for a crazy amount of time (minutes). My friend asked what scenario required that and it was something like this: Guy at a construction site can't start his bulldozer. He doesn't have jumper cables, but he's got an arc welder... I don't know if that actually happened but it would not surprise me.