There are two problems:
a) There is no appropriate extinguisher when you have a thermal runaway on 20 kWh of chemical energy.
b) This isn't some shielded, extinguisher-nearby, one-time experiment, when you, for example, solder something off and then while yelling "see, I'm still alive!" run outside and throw it out. This is something that is intended to be running 24/7 at your home (and maybe mounted on wooden wall like the pictures in the link...). Unless you post guard duty shifts around the clock, there simply may be no person to perform the plan of getting failed cells onto concrete.
I see this as super-dangerous, especially when dealing with cells from many different vendors scavenged from thrown-out laptops.
And the extinguisher would be for things around where the batteries used to be, in a catastrophic failure.
Yes there is, it's called a hose. But you're right, that 20 kWh isn't just going to up and disappear. I think it's realistically possible to do this with a modicum of safety even for a hobbyist but it needs to be passively safe. It can't rely on cells being inherently balanced with respect to one another, it needs to have some serious thought about what to do with that 20 kWh if the worst occurs but that's not an insurmountable task. Sprinkler heads are cheap and even just a garden hose will put out 25 gallons a minute. A very slight risk of water damage can be acceptable IMHO, I wouldn't have trouble sleeping with something cobbled together sitting in my garage so long as I planned for the worst along the way when piecing it together.
Of course, then you run into cooling and maintenance access issues.
I sure as shit would not want 1/10th of that in my garage ever.
Thanks
But be sure to protect them, and be aware that most commercial li-ion chargers and off-the-shelf protection circuits are designed to maximize short-term battery life. They'll charge to 4.2V, and many won't cut off until 2.5V.
Also know what to do if they short and catch fire; have an appropriate extinguisher and a plan for quickly getting failed cells outside and onto an inert surface like concrete.
If you want to make a 'powerwall' whose batteries could last you for a significant amount of time (e.g. decades), you'll also probably want to design your own charging and undervoltage protection circuits.
There's some good information here: http://batteryuniversity.com/learn/article/how_to_prolong_li...