Someone put a lot of thought into the design. Ground at top to prevent accidents like you show. Ground pin is longer. Insulation covers enough of the pins that live and neutral disconnect before conductor is exposed from socket. Both will be fully disconnected before earth disconnects.
If you actually look at a NEMA 5 outlet with the ground pin compared to old ungrounded polarized NEMA 1 outlets the NEMA 5 outlet is rotated 180 degrees. The larger neutral slot is on the right on old outlets and with the ground pin down on a NEMA 5 outlet the neutral is on the left.
It's not just for people dropping coins or paper clips on it though. Some outlet covers are metal and if the screw is loose or damaged that's basically guaranteed to short out if something is plugged in with the ground pin on the bottom. Another common thing is people using a tape measure along a wall, it's so thin that if there's a small gap it could shock someone using it or if you're lucky just short against the neutral.
https://i.redd.it/bm1gqw8hzppz.jpg
Of course that's an ungrounded plug so they're in trouble either way, but you get the idea.
Another option (which I've never seen in the US) is plugs where the first chunk of the line/neutral prongs are insulated:
http://www.liddellappliancetesting.co.uk/ESW/Images/insulate...