You might need more then one probe for instance you might have one current probe that was accurate at a lower current but could not measure the higher current, and a second probe for the high current. Then process the data using the appropriate instrument depending upon the current.
I haven't done much w/ AC power measurements, but it's a common enough problem (large dynamic current range) for DC power measurements. Agilent (now Keysight) make instruments like the N6705B DC Power Analyzer that can sample a pretty high rates (like 10's of uSeconds) and be accurate at both uA range and 100's of mAs for dynamic current. I would imagine you could rig up something similar for AC power measurements.
http://doc.utwente.nl/102016/1/Runaway_energy_Meters.pdf
In this paper, it seems they were using an electromechanical meter (i.e. the analog style that predated digital) for reference because that's what consumers were using. This is measuring energy, obviously, not current.
http://www.dranetz.com/product-services/current-dranetz-prod...
here's the original paper http://ieeexplore.ieee.org.sci-hub.bz/document/7866234/?relo...
I was asking what measures the current.