Re:Want an energy efficient datacenter? Build it underwater by Florin_Andrei on Tuesday February 21, 2017 @05:35PM (#13700780)
> Salt water is highly corrosive.

To metals. Not so much to plastics.

> Isn't marine biology highly sensitive to heat pollution?

Isn't land-based biology highly sensitive to heat pollution?

Re:Want an energy efficient datacenter? Build it underwater by smallnamespace on Tuesday February 21, 2017 @05:42PM (#13700838)
> Isn't land-based biology highly sensitive to heat pollution?

No, land-based organisms comparatively have a much, much higher tolerance to temperature swings.

Water's high heat capacity and conductivity means that most marine environments have extremely stable temperature ranges (a few degrees one way or other), so most marine species are adapted to live in only that range, and quickly die otherwise. Tropical fish are hard to keep alive precisely for this reason.

Air temperature varies much more widely depending on time of day, season, and weather, so terrestrial organisms have all developed extensive strategies for thermoregulation (e.g. mammals, birds). For example, dogs can survive in both arctic and tropical environments.

Plus, while heat is naturally dissipated upward, underwater thermal plumes are more likely to affect fish than above-ground plumes would affect birds.

FYI, Cornell uses lake water to cool several campus buildings, and they needed to carefully review that the warmer return water wouldn't negatively affect fish [1].

[1] https://energyandsustainability.fs.cornell.edu/util/cooling/...

Re:Want an energy efficient datacenter? Build it underwater by ouid on Tuesday February 21, 2017 @06:33PM (#13701296)
Sunlight imparts about a kilowatt per square meter to the surface of the ocean at noon, I'm not exactly sure how to use that information, but it does seem relevant for bounding the problem.
Re:Want an energy efficient datacenter? Build it underwater by saeranv on Tuesday February 21, 2017 @07:45PM (#13701794)
This gets a lot lower with differing latitudes and seasonal and daily cloud cover/evening time - closer to 100 W/m2 [1]. So over a day you'd get 2.4 kWh. In comparison an electric space heater uses about 1 kWh of energy in an hour.

So how much will 2.4 kWh change the temperature of a cubic meter of water at the ocean surface?

Density of water = 1000kg/1m3 so mass = 1000 kg

2.4 kWh = 8640 kJ

Heat_Energy = Conductance * Mass * change_in_temp

8640kJ = 4.186 kJ/(kgā‹…K) * 1000kg * xC

x = 2C

So solar heat will change the first meter of water by about 2C over the course of a day. That's a small number b/c solar radiation is not a huge contributer to temperature swings. Instead what will effect the temperature difference is the seasonal change. If we can calculate the heat energy gained or lost due to seasonal extremes and water temp, then we can figure out what the range of acceptable heat energy is for surface water.

[1] https://www.withouthotair.com/c6/page_38.shtml

ETA: logic.

Re:Want an energy efficient datacenter? Build it underwater by afarrell on Tuesday February 21, 2017 @06:43PM (#13701372)
The specific heat of water is much higher than that of air.
Re:Want an energy efficient datacenter? Build it underwater by klodolph on Tuesday February 21, 2017 @07:07PM (#13701548)
Right, but the data center heat output will also be measured in (mega)watts.
Re:Want an energy efficient datacenter? Build it underwater by walrus01 on Tuesday February 21, 2017 @05:58PM (#13700991)
> To metals. Not so much to plastics.

I'm guessing you've never experienced the joys of owning a 30 to 40 ft sized, completely non metal (fiberglass hull) sailboat kept in salt water, with all of the great fun of paying to haul it and have the marine growth scaped off, pressure washed, double or triple coat bottom paint re-applied, etc. Just because it's not metal doesn't mean it doesn't attract the category of what the maritime industry lumps together as "marine fouling".

Re:Want an energy efficient datacenter? Build it underwater by Xylakant on Tuesday February 21, 2017 @06:01PM (#13701017)
Though marine fouling is primarily of concern for fiberglass boats because it massively increases drag which admittedly is less of an issue for a datacenter. It's still an issue for the pods as mentioned in the article, but I'd expect it to be less grave than on a boat.
Re:Want an energy efficient datacenter? Build it underwater by walrus01 on Tuesday February 21, 2017 @06:05PM (#13701057)
But I require a datacenter with a hull speed of at least 7.5 knots.
Re:Want an energy efficient datacenter? Build it underwater by Xylakant on Tuesday February 21, 2017 @06:09PM (#13701085)
let me double check the hull speed formula for datacenters.
Re:Want an energy efficient datacenter? Build it underwater by baking on Tuesday February 21, 2017 @06:05PM (#13701054)
Marine fouling of the heat exchangers is probably the biggest technical hurdle.
Re:Want an energy efficient datacenter? Build it underwater by Xylakant on Tuesday February 21, 2017 @06:07PM (#13701066)
Yes, as well as keeping all kinds of marine life out of there.
Re:Want an energy efficient datacenter? Build it underwater by andrewflnr on Wednesday February 22, 2017 @01:08AM (#13703429)
GP was quite specifically taking about chemical corrosion, not bio-fouling. Even if the marine industry conflates these (I can't tell if that's what you're implying in the last sentence), we don't have to.
Re:Want an energy efficient datacenter? Build it underwater by ch4s3 on Tuesday February 21, 2017 @06:15PM (#13701117)
Plastics are good, but you need to have tubes going into the thing, as well as some means of accessing the inside even if you only access it on a ship/land. That means rubber and metal will have to be on the exterior somewhere.