Where I am from we have installations differently. phase and neutral come in the box, they go through a loss breaker(RCD) and then split up in to multiple breakers. Then those wires go to the socket. Then near the box there is a metal rod in the ground with a wire going to the box, this wire connects to the ground wires coming from sockets. The ground wire, is not connected to anything but things that are not supposed to have any power flowing through.
Yes Neutral is grounded (outside my house, on the main) But when we say we ground things we mean the third connection.
Sorry, didn't know it was so different over there.
edit: Saw the correct name for the "loss breaker" in other post, it is RCD :)
edit: Question, what happens if you hold the neutral to the ground wire there?
Forgive my ignorance, I'm no electrical expert, but did you just say that the ground wire is connected to the neutral somewhere in the circuit? Or did I misunderstand you?
EDIT: That "always" is assuming the house is modern wiring and not older-style two-prong wiring for the wall outlets. Those systems were just main and neutral at the box and controlled by a fusible link.
If I'm understanding you correctly, in the US the ground wire is functionally identical to the neutral due to the bonding. Therefore (this is my own deduction and I'd appreciate being corrected if I'm wrong) you could, in theory, invert the ground and neutral wires in the plug of an electrical appliance and there would be no change in the behaviour or safety of the appliance?
Generally, no. I've seen backwards wiring jobs cause 48-80VAC to run through the casing of microwaves (they usually use the casing as a floating ground.) Any wiring inversion will usually cause some issue somewhere.
http://ecmweb.com/code-basics/grounding-and-bonding-part-2-3
Same way you complete any other ground - since ground and neutral are literally on the same leg (go look at any installation. You've got TWO wires coming in at the mains, ungrounded.)
So, tell me, how do you ground those ungrounded 240/277V wires??
You don't. Both of them ARE the natural ground dependent upon whether you're at the peak or trough of the waveform. That's kinda how AC works.