Re:What does a kilowatt hour look like? by qoobaa on Friday September 23, 2016 @04:24AM (#12563112)
I think @gravypod actually meant parallel connection, it might be quite dangerous in fact - you don't even need to draw anything from the battery to mess things up. If you connect a 100 cells in parallel and one cell dies creating a short in the circuit, the rest of cells will discharge through the shorted one. When you short a single 18650 cell, it outputs about 6-7 A of current on average. Multiplying by 100 gives you 600-700 A of current flowing through a single cell. That's why people use fuses to create parallel modules.
Re:What does a kilowatt hour look like? by gravypod on Friday September 23, 2016 @07:47AM (#12563838)
Yes that was mentioned in one of the maaaany EEVBlog videos iv watch that these fail closed sometimes as well as the recommendation that "you should never buy lipo cells without a built-in controller" comeing from a guy far smarter then I about electronics design. If he is afraid of it, it's for a good reason.
Re:What does a kilowatt hour look like? by throwaway7767 on Friday September 23, 2016 @10:29AM (#12564867)
> Yes that was mentioned in one of the maaaany EEVBlog videos iv watch that these fail closed sometimes as well as the recommendation that "you should never buy lipo cells without a built-in controller" comeing from a guy far smarter then I about electronics design. If he is afraid of it, it's for a good reason.

If you're building a large pack you don't want cells with a built-in protection. You connect all the cells to a pack-wide BMS that keeps things safe.

The important thing is to never use unprotected cells without some protection circuit in the pack.