Re:CDC warns coffee workers of hazardous chemicals
by jdnier on Sunday October 18, 2015 @02:40PM
(#10409207)
But there are different levels of respirators, some with filters for organic vapors, which I think you'd want if your goal is lowering diacetyl and 2,3-pentanedione exposure.
Re:CDC warns coffee workers of hazardous chemicals
by ars on Sunday October 18, 2015 @02:59PM
(#10409298)
One rated OV for Organic Vapor should be enough.
Evidence:
https://www.aiha.org/events/AIHce/AIHceAbstracts/Pages/Respi...
Section "SR-101-02 Determination of the Service Life of Air-Purifying Respirators against 2,3-Pentanedione"
I think the science is not settled yet, which is why they are having a hard time making an exposure rule, but:
"NIOSH noted that five of six current employees who worked in the quality control room popping nearly 100 bags of product in microwave ovens per shift suffered airway obstruction despite relatively low full shift exposure to butter flavoring vapors."
http://www.gpo.gov/fdsys/pkg/FR-2009-01-21/pdf/E9-1125.pdf
From what I read about it seems like a cumulative hazard with no known safe level, every exposure does some damage. So I would install ventilation, or just buy a gas mask (they are not expensive, you can get them at a hardware store, probably cheaper than a ventilation system).