Kirchoff's Voltage Law (sum of voltages around a loop is zero) breaks when there's a changing magnetic field poking through the loop. The amount it breaks by is V=A*dB/dt where V is "extra" voltage, A is area of the loop, and dB/dt is change in magnetic field with time.
An EMP creates a shockwave of enormous dB/dt. Even loops with small A can induct enough voltage to fry sensitive electronics.
A CME has dB/dT of 5mT/min (linked article). Fridge magnets are ~5mT (wikipedia) so you could make a local field with similar dB/dt by walking very slowly towards your computer while carrying a fridge magnet. Of course, unlike fridge magnet vs computer, CMEs are damaging because A is massive (distribution infrastructure is a big loop) so even though dB/dt is tiny they can fry power lines.
That is, unless real-time distribution management notices voltages starting to go haywire and shuts them down because a CME isn't instantaneous and hard to anticipate like an EMP. Or circuit breakers do their job because voltage / km is relatively small. Or inductive loads (anything with a motor or transformer in the circuit) protect themselves from what essentially looks like just another voltage spike (they happen all the time because every time you shut off a poorly designed inductive load it kicks a high voltage back onto the line). Or TVS diodes do the same for sensitive electronics somehow connected without a transformer...
tl;dr a CME is not like an EMP. Same physics equation but with very different numbers.