Re:Utility poles
on Friday February 16, 2018 @08:58PM (#16398411)
That's a higher voltage power line (in the low kV range) with just the three phases. They're relying on the load being approximately distributed between the three in the downstream distribution network to obviate the need for any return wire. If you move forward one step on that road you will see the next pole has a lower set of wires which will be at 230/240 volts. On these it looks like there are four wires, they're probably doing without the earth wire in this rural area and just tying to earth periodically.
Re:Building Your Own CDN for Fun and Profit
on Thursday February 15, 2018 @05:43AM (#16383075)
Did you consider using periodic calls to keep the Lambda@Edge functions "warm"? I've been playing with Zappa (https://www.zappa.io) for standard Lambda and it sets this up by default.
Re:Utility poles
on Thursday February 15, 2018 @01:35AM (#16382313)
I think New Zealand is the same as Australia with 5 wires: the 3 phases, neutral (the central return wire) and earth. Grabbing a random location in Auckland off Street View shows 5 wires:
Re:Utility poles
on Wednesday February 14, 2018 @09:41PM (#16381541)
Not so much bushfires damaging electrical infrastructure as electrical infrastructure starting fires. A large portion of Victoria's worst day of bushfire was sparked by a faulty power line and the electricity distribution network (22kV and below) is responsible for a good portion of fire starts, especially those lines that utilise a single wire with an earth return (SWER). The recommendations of the Royal Commission into the Black Saturday fires in regard to the electricity network are available at http://royalcommission.vic.gov.au/Commission-Reports/Final-R... and contain a whole lot of background information. Suffice to say that the recommendation (27) of the wholesale burying of thousands of kilometres of SWER line at the cost of billions of dollars haven't gone far.